Refrigerator battery calculator
Estimate how long a published battery capacity covers your refrigerator’s average draw, and the watt-hours a duration needs. Watts are a rate. Watt-hours are an amount. A battery can have enough watt-hours and still fail to start the compressor.
Worked example, before you enter your own numbers
A refrigerator that uses 500 kWh per year averages 57.0776 W. The 10 W idle allowance is added first, so the AC-equivalent load is 67.0776 W. For a 2,048 Wh battery, the exact runtime is 23.3568 hours. Rounded to one decimal, that is about 23.4 hours. The minimum capacity for 24 hours is 2,104.4 Wh. That is 56.4 Wh more than 2,048 Wh, so this capacity does not cover the full 24-hour plan.
| Model | Capacity | Continuous | Published surge | Planning result | Source check | Link |
|---|---|---|---|---|---|---|
| EcoFlow DELTA 3 Plus | 1,024 Wh | 1,800 W | 3,600 W | Shortfall: 1,080.4 Wh below the planning minimum. Planning runtime 11.7 hours. | Spec block matched 1,024 Wh, 1,800 W total, and 3,600 W surge. The same page also describes an X-Boost figure of 2,200 W, which is not the continuous rating used here. | Manufacturer information (opens in a new tab) |
| Jackery Explorer 1000 v2 | 1,070 Wh | 1,500 W | 3,000 W | Shortfall: 1,034.4 Wh below the planning minimum. Planning runtime 12.2 hours. | A specifications row matched 1,070 Wh, 1,500 W rated, and 3,000 W surge. A description sentence on the same page says 1,024 Wh. This site did not replace 1,070 Wh. | Manufacturer information (opens in a new tab) |
| Jackery Explorer 2000 v2 | 2,042 Wh | 2,200 W | 4,400 W | Shortfall: 62.4 Wh below the planning minimum. Planning runtime 23.3 hours. | Official text matched 2,042 Wh, 2,200 W continuous, and 4,400 W surge. The manufacturer’s refrigerator wording on that page is not a test by this site. | Manufacturer information (opens in a new tab) |
| EcoFlow DELTA 3 Max | 2,048 Wh | 2,400 W | 4,800 W | Shortfall: 56.4 Wh below the planning minimum. Planning runtime 23.4 hours. | Official text matched 2,048 Wh, 2,400 W output, and 4,800 W surge. An X-Boost mention of appliances up to 3,400 W is not used as the continuous or surge rating. | Manufacturer information (opens in a new tab) |
Your refrigerator
[{"id":"delta-3-plus","brand":"EcoFlow","name":"DELTA 3 Plus","capacityWh":1024,"continuousW":1800,"surgeW":3600,"href":"https://us.ecoflow.com/products/delta-3-plus-portable-power-station","rel":"noopener noreferrer","label":"Manufacturer information","affiliate":false},{"id":"explorer-1000-v2","brand":"Jackery","name":"Explorer 1000 v2","capacityWh":1070,"continuousW":1500,"surgeW":3000,"href":"https://www.jackery.com/products/jackery-explorer-1000-v2","rel":"noopener noreferrer","label":"Manufacturer information","affiliate":false},{"id":"explorer-2000-v2","brand":"Jackery","name":"Explorer 2000 v2","capacityWh":2042,"continuousW":2200,"surgeW":4400,"href":"https://www.jackery.com/products/jackery-explorer-2000-v2-portable-power-station","rel":"noopener noreferrer","label":"Manufacturer information","affiliate":false},{"id":"delta-3-max","brand":"EcoFlow","name":"DELTA 3 Max","capacityWh":2048,"continuousW":2400,"surgeW":4800,"href":"https://us.ecoflow.com/products/ecoflow-delta-3-max-portable-power-station-2048wh","rel":"noopener noreferrer","label":"Manufacturer information","affiliate":false}]
Enter the energy use and choose Calculate. The math stays in this browser. The worked example above remains available if JavaScript is off.
What the inputs mean
Annual kilowatt-hours become average watts by multiplying by 1,000 and dividing by 8,760, the hours in a non-leap year. A measured average is used as-is. Running watts times a duty-cycle fraction is another average. All three describe energy over time, not the brief startup spike.
Continuous watts on a power station are the output it is published to hold. Surge watts are a short published peak. Compare those ratings only to a startup figure you actually know. If you do not know it, this page will not pretend the comparison happened.
Efficiency, reserve, idle, age, and temperature move the real result. A cold garage, an old battery, or a refrigerator that runs more because the kitchen is hot can use the reserve you set aside. The defaults are planning choices: efficiency 0.85, reserve 0.10, and a 10 W idle allowance added to average watts before that efficiency is applied.
Read the full method, the watts explainer, and the EnergyGuide page before treating a result as a shopping decision.
Common questions
Does matching the watt-hours mean my refrigerator will run?
No. The result is an energy estimate under the assumptions you leave in the form. It does not confirm the compressor will start, and it does not measure food temperature.
What if I do not know startup watts?
Leave the field blank. Startup compatibility is not confirmed, and the published surge figures are not compared. You still get the energy estimate.
Where does the 10 W idle go in the formula?
It is an AC-equivalent allowance added to average watts before inverter efficiency. Runtime is capacity × 0.85 × 0.90 ÷ (average watts + 10). There is no second, hidden derating.